1. Check if the circuit of the air cooler water pump is damaged. If it is damaged, replace the water pump and connect it to the power source to ensure that the water pump is powered on;
2. Check for dirt at the inlet of the water pump, and promptly clean or replace the water in the sink if there is any dirt;
3. Check the water pump rotor to ensure that it is not damaged or blocked.
4. Please disconnect the power before checking the air cooler;
5. The water pump of the air cooler cannot dry burn when there is no water;
6. Do not directly pick up the water pump with the power cord;
7. Do not operate the air cooler water pump in hot water;
8. Check the head size and normality of the air cooler water pump when working in clean water
Article source: Cooling fan water pump http://www.xxmh512.com
06-01
Reasons for high temperature of DC brushless water pump
The power supply voltage is high, exceeding the additional voltage of the motor by more than 10%, causing an increase in motor iron loss and causing the motor to heat up. DC brushless water pumpIf the
05-12
DC brushless water pump: The advantage of brushless DC pump replacing AC pump
In recent years, DC pumps have become well-known among many companies due to their small size, low power, and high safety factor. Engineers will consider upgrading the original communication pump to a
04-02
DC booster pump: How to choose a water heater booster pump
The booster pump of a water heater is an important accessory in a water heater, and its quality directly affects the quality, brand, and reputation of the water heater. Therefore, when selecting a boo
02-14
DC booster pump: a key task in DC pump management
From the fundamental perspective of handling demands, manufacturers of DC water pumps pursue input-output, which means pursuing the efficiency of DC water pump adoption and operation. From this perspe